Protected Memory Error

Labels: error message error protected memory memory corrupt post-seer energy savings corrupt memory

Energy Savings could not be calculated because of the following:
Attempted to read or write protected memory. This is often an indication that other memory is corrupt.

Here are possible reasons:

1)    Missing post SEER on heating/cooling record.

  1. Fix:  Edit record, change the pre-SEER, save, edit and change it back.  The post-SEER is automatically calculated.

2)    Missing zonal distribution record, or one or more heating/cooling records are not tied to a zonal distribution record.

  1. Fix:  Check zonal records and make sure all heating/cooling records have been selected.  If a record is missing have the agency user update the record.

3)    One or more weatherization, baseload, or DHW screens is missing a required field.

  1. Fix:  Edit each screen and save.  If a required field is missing you will get a notification.  Have the agency user update that field.

4)    Special characters in measure name.

  1. Fix:  Check measures for single or double quotes.  Edit measure and change to ‘ft' or ‘in' as appropriate.

5)    Window/door sections not associate with any wall section.

  1. Fix:  Have the agency user either delete the extra windows/doors or add them to the appropriate wall.

6)    A measure is marked as both energy saving and healthy & safety.

  1. Fix:  Have the state office update the measure to be one or the other.